The APsystems EZ1 plug-in microinverter makes small-scale solar accessible for balconies, patios, gardens, and other DIY setups. It connects to compatible solar panels and supplies AC electricity to your home through a standard 120V outlet connection, where permitted.
Simple installation starts with understanding the equipment. Using compatible panels, selecting an appropriate outlet, following the product instructions, and checking local requirements all help support a safe installation.
What is the APsystems EZ1?
The U.S. EZ1-LV is a grid-connected microinverter with two independent solar-panel input channels. Each channel has its own Maximum Power Point Tracking, or MPPT, allowing it to manage the connected panel independently.
One EZ1-LV provides up to 900VA of continuous AC output at a nominal 120V, with a nominal output current of 7.5A. Built-in Bluetooth and Wi-Fi allow setup and monitoring through the AP EasyPower app.
The current U.S. documentation identifies balcony, garden, garage, and carport applications. It explicitly states that EZ1-LV is not suitable for rooftop system applications.
What safety certifications does EZ1 have?
APsystems identifies EZ1 as CSA certified to UL 3700 standards and meeting UL 1741 SB requirements.
Product certification and installation approval serve different purposes. Certification does not automatically establish that every outlet, circuit arrangement, or installation is permitted. Owners must also follow the product instructions and requirements that apply to their location.
What happens during a power outage?
EZ1 includes anti-islanding protection. When utility power fails, the inverter automatically stops producing power, helping prevent electricity from feeding onto utility lines during an outage.
Before restarting, EZ1 must detect stable grid voltage and frequency for five minutes.
EZ1 requires a functioning utility grid. It does not provide standalone backup power or operate as an off-grid inverter. A portable EZ1 setup is still a grid-connected solar system.
How is anti-islanding different from zero-export control?
Anti-islanding stops generation when the utility grid goes down. Zero-export control manages excess solar production while the grid is operating.
During normal operation, EZ1 supplies solar electricity to household loads. If solar production exceeds the electricity the home is using, excess power may flow to the utility grid.
The optional APmeter monitors power flow at the homeβs electrical panel and automatically adjusts EZ1 output to help prevent excess solar electricity from being sent to the grid, commonly called backfeed.
APmeter is sold separately. Its installation at the electrical panel must follow applicable electrical codes and local requirements. Zero-export control does not, by itself, establish that an installation is exempt from utility or permitting requirements.
What outlet should be used?
EZ1-LV uses a standard 120V plug connection, but the outlet and its branch circuit must be suitable for the installation.
Before connecting the system, confirm:
- The outlet voltage matches the inverterβs rating.
- The receptacle is properly grounded and in good condition.
- The circuit arrangement and system output meet applicable requirements.
- Outdoor receptacles and connections have the required ground-fault and weather protection.
Do not use an outlet with loose contacts, visible damage, scorching, or signs of overheating. Have a qualified electrician assess questionable outlets or wiring.
A standard plug connection should not be treated as permission to connect to any available receptacle.
Which power cord and extension cables should be used?
Use the APsystems power cord intended for EZ1-LV and follow the current installation instructions for connecting and securing it. Do not cut, splice, or modify the proprietary AC connector.
APsystemsβ current FAQ permits AC extension cables when they are rated for outdoor use, UV resistant, weather sealed, and properly sized for the distance. Applicable rules for temporary and permanent wiring must also be followed.
If additional cable length is needed, contact APsystems Technical Support for guidance on the appropriate cable and connection arrangement. Do not assume a household power strip, splitter, or adapter is suitable for connecting the system.
AC power cords and DC panel cables have different requirements. Follow the current documentation for each rather than applying one cableβs specifications to the entire system.
How should EZ1 be mounted outdoors?
The supplied U.S. EZ1-LV documentation specifies a Type 6 enclosure rating. The mounting instructions still matter: position the inverter to avoid direct exposure to rain, UV, and other harmful weather where possible.
Secure the inverter using an appropriate mounting method and leave at least 2 cm, approximately ΒΎ inch, of clearance above and below its casing for airflow.
Do not carry the inverter by its AC cable. Its casing also functions as a heat sink and can become hot during operation.
How do you check solar-panel compatibility?
Panel wattage alone does not establish compatibility with EZ1.
Check the panelβs voltage and current specifications against the current EZ1-LV datasheet and APsystemsβ module compatibility resources. EZ1-LV has a DC operating voltage range of 26β60V, a maximum input voltage of 60V, and a maximum input current of 18A per channel.
The 26V minimum is important: a panel with insufficient operating voltage may not operate properly with EZ1, even if its wattage appears suitable. Check the panelβs operating voltage (Vmp), not just its open-circuit voltage (Voc), and use APsystemsβ compatibility resources to confirm your selection.
Each panelβs positive and negative leads must connect to the same input channel. Follow the installation documentation for connector requirements and cable-length limits.
Can two EZ1 units be connected?
The EZ1-LV datasheet specifies a maximum of two electrically connected units. Use the APsystems cable accessories intended for that configuration and confirm the permitted output and circuit arrangement before expanding a system.
App monitoring capacity is a separate specification. The ability to monitor additional devices does not authorize connecting more inverters to the same cable or circuit.
Does EZ1 require a dedicated circuit, permit, or utility notification?
Requirements depend on the jurisdiction and installation configuration. State rules, locally adopted electrical codes, utility requirements, and system output can affect what is permitted.
Confirm the requirements for your location before connecting the system.